LeakNet LP offers remote meter readings via cellular, with quick installation, 15-minute reads, and 12-year battery life.
Request A Quote Download The Brochure


Designed for locations without mains power, LeakNet LP provides cellular meter readings with fast installation, long battery life and clear usage data through FlowReporter.
Regular meter readings to support water usage tracking and abnormal flow detection.
Quick to install, making it suitable for automatic meter reading and smart meter strategies.
Long-term low power operation, depending on configuration and upload frequency.
Remote data transfer without relying on WiFi or a fixed site network.
View usage by day, month or year, compare devices and support intelligent leak alerts from one dashboard.
Where power is not available, LeakNet LP (Low Power) is the ideal device for collecting remote meter readings via cellular network.
It is a low cost, fast option for implementing automatic meter reading or smart meter strategies. Installation can be done in as little as 10 minutes.
Once installed, the the meter is read every 15 minutes and upload frequency can be programmed with a battery life of up to 12 years (see specs below).
All data is displayed in FlowReporter on any smart device or laptop, where usage can be viewed by day/month/year, compared with other devices, and where intelligent leak alerts can be learnt.

Industrial-grade cellular connectivity (GPRS/GSM) transmits alerts and usage data where fixed broadband is unavailable or unreliable.
Why it matters: construction sites, remote assets, and early-phase builds rarely have stable LAN infrastructure. Cellular backhaul keeps monitoring live from day one, so teams are notified during the highest-risk periods instead of after permanent comms are installed.
Built into SiteNet for Construction and LeakNet LP Data Logger for dependable reporting without dependency on site WiFi.
Automated machine learning continuously learns normal water consumption patterns for each site, establishing baselines without manual threshold tuning.
Why it matters: fixed flow limits generate false alarms in buildings with variable occupancy, seasonal plant, or mixed-use profiles. Adaptive learning reduces nuisance alerts, catches subtle anomalies earlier, and helps facilities teams focus on genuine escapes rather than routine usage spikes.
Included across LeakNet Gen2, LeakNet Gen1, Flow Sensors & Meters, and LeakNet LP Data Logger, giving portfolio-wide intelligence from permanent installs to remote metering.
An IP68-rated outdoor enclosure protects hardware from rain, dust, and temperature swings on external or semi-exposed installs.
Why it matters: water infrastructure often lives outside the conditioned core of a building. Weatherproofing reduces failure rates, extends service life, and avoids the false sense of security that comes from equipment that only works in perfect conditions.
Standard on SiteNet for Construction and LeakNet LP Data Logger for yards, plant enclosures, and external meter chambers.
Alerts can be sent to multiple stakeholders simultaneously: facilities, security, contractors, and estate managers, so the right people respond without single-point dependency.
Why it matters: water events do not respect org charts. Multi-recipient alerting reduces delay when the primary contact is off-site and creates an auditable chain of notification for insurers and compliance reviews.
Available across Leak Cable, Splash Sensors, LeakNet LP Data Logger, and SiteNet for Construction.
Instant notifications via SMS, email, and the FlowReporter mobile app keep teams informed wherever they are working.
Why it matters: different roles live on different channels. Multi-channel alerting maximises the chance someone actionable sees the event within minutes, which is critical when average escape-of-water claims run to thousands of pounds per hour of unchecked flow.
Standard across LeakNet Gen2, LeakNet Gen1, Flow Sensors & Meters, LeakNet LP Data Logger, and SiteNet for Construction.
Quensus flow-based devices accommodate pipe sizes up to 8″, so a single monitoring approach can cover mains supplies across commercial, industrial, and multi-occupancy buildings without forcing a downgrade in measurement quality.
Why it matters: estates often mix pipe diameters between plant rooms, risers, and tenant supplies. A platform that scales with pipe size reduces bespoke engineering, speeds specification, and keeps leak thresholds meaningful on high-volume lines where small percentage losses still mean large volumes of water.
Available on LeakNet Gen2, LeakNet Gen1, Flow Sensors & Meters, LeakNet LP Data Logger, SiteNet for Construction, and Valves. The same capability supports everything from permanent building installs to temporary site protection.
Device has a built-in LED indicator for showing the current flow rate.
Monitor the flow rate at this moment in time remotely from the app, making it easy to find & fix leaks.
View consumption in events/minutes/days/months and what this means in terms of bills.
Compare different areas or locations to provide reports and enhance anomaly detection.
Group devices to provide enhanced reporting, comparison and anomaly detection
Device has a built-in audible alarm for alerts.
BMS Output (Alert and/or valve status).
Protect large areas with a 5m-100m leak cable for immediate detection of leaks.
Monitor the ambient temperature and automatically shut the water off to prevent freezing.
Remote programming of device.
Integration with wireless splash sensors.
Receive real-time leak notifications on your phone for rapid response.
Get multiple alert channels (SMS, Email) to ensure critical issues aren't missed.
Via app notification, SMS and email alerts.
Override alerts at set dates if you are expecting a temporary change in usage (high or low).
Advanced algorithms pinpoint even the smallest drips, enhancing low flow accuracy of flow sensors.
Shut-off immediately to prevent damage from burst pipes using the maximum flowrate normally observed.
Harness the power of machine learning to adapt leak detection based your normal usage
Automatic shut-off using maximum time, volume, flowrate, leak cable
Compatible with solenoid and motorised valves up to 8".
Valve bypass for fire sprinkler override functionality.
Remotely shut the water off or open the valve to let water through and temperature (freezing)
Scheduled shut-off and open at different times of the day.
Automatically shut off water supply in areas of prolonged inactivity to prevent waste and mitigate risks.
Identify areas where water has been stagnant for preset period and purge water supply to mitigate legionella risk.
Ensure the reliability and longevity of your fittings by regularly exercising valves to prevent seizing.
Always have the latest firmware.
Shared access with unlimited users.
No WiFi? No problem. We can provide a completely closed, plug-and-play system.
Peace of mind with up to 3 years (LeakNet panel) and 5 years (splash sensors) coverage.
Get replies within a day about your issue
Making sure devices are installed correctly.
Helping you to make sense of the data, program alerts, and co-ordinate leak finding and fixing
Tailored water management plan that builds around your needs
Guarantee proper installation and end-user training for optimal performance.
Clear guidance for leak response, minimising confusion.
Streamline the design process with expert consultation and clear installation specifications.
Seamlessly integrate realtime water data with your existing building management systems, analytics platforms, or custom applications.
Receive custom monthly reports highlighting water usage, leak alerts, and savings opportunities. Easily prove sustainability goals and other KPIs.
Device has a built-in LED indicator for showing the current flow rate.
Monitor the flow rate at this moment in time remotely from the app, making it easy to find & fix leaks.
View consumption in events/minutes/days/months and what this means in terms of bills.
Compare different areas or locations to provide reports and enhance anomaly detection.
Device has a built-in audible alarm for alerts.
BMS Output (Alert and/or valve status).
Protect large areas with a 5m-100m leak cable for immediate detection of leaks.
Remote programming of device.
Monitor the ambient temperature and automatically shut the water off to prevent freezing.
Integration with wireless splash sensors.
Harness the power of machine learning to adapt leak detection based your normal usage.
Get multiple alert channels (SMS, Email) to ensure critical issues aren't missed.
Via app notification, SMS and email alerts.
Override alerts at set dates if you are expecting a temporary change in usage (high or low).
Advanced algorithms pinpoint even the smallest drips, enhancing low flow accuracy of flow sensors
Shut-off immediately to prevent damage from burst pipes using the maximum flowrate normally observed.
Harness the power of machine learning to adapt leak detection based your normal usage.
Automatic shut-off using maximum time, volume, flowrate, leak cable.
Compatible with solenoid and motorised valves up to 8".
Valve bypass for fire sprinkler override functionality.
Remotely shut the water off or open the valve to let water through and temperature (freezing).
Scheduled shut-off and open at different times of the day.
Automatically shut off water supply in areas of prolonged inactivity to prevent waste and mitigate risks.
Identify areas where water has been stagnant for preset period and purge water supply to mitigate legionella risk.
Compare different areas or locations to provide reports and enhance anomaly detection
Always have the latest firmware.
Shared access with unlimited users.
Insurance requirements are getting more stringent, but we are here to help with best practices.
No WiFi? No problem. We can provide a completely closed, plug-and-play system.
Group devices to provide enhanced reporting, comparison and anomaly detection.
Get replies within a day about your issue.
Making sure devices are installed correctly.
Helping you to make sense of the data, program alerts, and co-ordinate leak finding and fixing.
Tailored water management plan that builds around your needs.
Guarantee proper installation and end-user training for optimal performance.
Clear guidance for leak response, minimising confusion.
Streamline the design process with expert consultation and clear installation specifications.
Seamlessly integrate realtime water data with your existing building management systems, analytics platforms, or custom applications.
Receive custom monthly reports highlighting water usage, leak alerts, and savings opportunities. Easily prove sustainability goals and other KPIs.

|
Connectivity
|
Cellular 2G / 3G / 4G / GPRS / GSM / LTE |
|---|---|
| Read Rate |
Every 15 minutes |
| Power | 3.6V Lithium Thionyl Chloride D Battery |
| Send Rate |
Monthly (12 years battery life) |
| Body |
IP Rating: IP68 |
| Dimensions | 120mm x 65mm x 60mm |
| Weight | 350g (with battery) |
| Electrical Connections |
Water Meter Input, |





